Skip to content
Facer Locksmith SpecialistsRequest a visit
Open 24/7(289) 432-1115Call now
Person holding a rectangular door-hardware housing at a table with additional metal assemblies beside a glass entrance. — Access Control Installation, Facer

Plan ahead Commercial · Facer

Access Control Installation in Facer

The keypad on the side door has started sticking on cold mornings, codes get shared instead of reset, and half the staff still remember a code you meant to retire two hires ago.

Call now · open 24/7(289) 432-1115

Request a visit

In plain words

Locking hardware varies by opening: an electric strike, fitted into the existing frame, keeps the mechanical latch and releases it briefly for a valid credential; a magnetic lock clamps the door shut with an electromagnet and suits a frame or door that will not take a strike; and some openings use an electromechanical lock or a different controlled lockset entirely. Several of these can also be fitted with a mechanical override cylinder, so a lost signal, a dead battery, or a controller fault still leaves that particular door opening by key, though the option depends on the hardware chosen for it.

Sound familiar?

The team has grown past the point where one shared key still makes sense. New hires need a way in before a manager arrives, and the current setup cannot tell one person's entry from another's.

How the visit goes

Access Control Installation · Facer

How the visit goes

Illustrative locksmith scene — Facer
  1. 1

    Checking which doors are also exits

    A door that leads outside along a path people use to leave the building gets special attention, no matter what lock currently sits on it, so the survey flags every one of those openings early. On an exit door, a magnetic lock only gets considered alongside a request-to-exit device and a tie-in to the fire alarm system, while an electric strike paired with a standard latch usually needs no extra hardware to let people out. Sorting exit doors from interior doors before any hardware is ordered keeps a smooth, one-motion exit part of the plan from day one rather than a fix added afterward.

  2. 2

    Enrolling cards, fobs and codes

    Once schedules and access levels are ready, each credential is enrolled against a name, presented at a reader or entered at an enrolment station, and assigned to the access level matching the person's role. A keypad code is set and confirmed working at the door itself; a card or fob is tested the same way before it is handed over. The locksmith keeps a running list during enrolment so nothing is issued twice and nothing is left unassigned, and hands that list to the administrator as the starting record for the system going forward.

  3. 3

    Reading the entry log

    Every controller keeps a record of which credential was presented at which door and when, and, where a door position switch is fitted, whether the door actually opened; that log is available to the administrator whenever it is needed, not only after something has gone wrong. Pulling a recent day's entries for the stockroom, checking whether the loading dock was opened outside its scheduled window, or confirming a contractor's credential was only used on the days they were on site are ordinary lookups rather than a special request, though the record shows the credential used rather than proof of who held it. Reviewing the log occasionally, rather than only when there is a problem, is a genuinely useful habit.

In the van

  • Keypad readers
  • Credential cards and fobs
  • Request-to-exit devices
  • Mechanical override cylinders
  • Fire alarm interface relay

What affects the quote

  1. 1

    Distance between the doors and the controller

    A building where every controlled door sits close to where the controller will be mounted needs less cable and fewer pull points than one with openings spread across several floors or a large footprint.

  2. 2

    Power supply and backup sizing

    A power supply and battery backup have to be sized to the number of doors and locks they support, and a building with several openings on one controller needs a larger supply than a single standalone unit.

  3. 3

    How many doors are being controlled

    A single entrance and a building with a dozen openings are different jobs in scale rather than kind, and the number of doors, readers and locks involved is the largest single factor in sizing the work.

Same fees day, night or weekend.

Have it ready

Before you call · 0 / 3

(289) 432-1115

Access Control Installation: questions

Advice · (289) 432-1115

What maintenance does the system need going forward?

Ongoing maintenance is light: checking the battery backup and the request-to-exit device periodically, keeping reader surfaces reasonably clean, and revoking credentials promptly once someone leaves. Door and frame alignment is worth a look at each change of season, since a shifted door can affect how cleanly an electric strike or a magnetic lock releases.

What happens to the doors if the power goes out?

Outage behaviour depends on how that opening was built: battery backup can be sized to carry the reader, the lock and the controller through a typical outage, so a brief power loss need not lock anyone out or, on a fire-alarm-tied opening, lock anyone in, but that backup and any mechanical key override are specified per opening rather than assumed for every door. Fail-safe hardware unlocks once power has been out longer than the backup lasts; fail-secure hardware stays locked, and what opens it depends on the hardware chosen.

Can access control go on a fire exit or a required exit door?

Yes, with extra care taken specifically because it is an exit. A magnetic lock on an exit door is paired with a request-to-exit device and wired into the fire alarm system so it releases automatically the instant an alarm activates, and the door is confirmed to open with one motion from the inside at all times. An electric strike on an exit door generally needs no additional egress hardware.

Niagara, Ontario

Facer information

Town
Facer, Niagara, Ontario
In business
12 years
Hours
Open 24/7 · nights, weekends and holidays, same fees
Visits
On-site assessment preferred. Request a visit or call.

What the census means at the door

71%

Older homes. About 71% of homes in St. Catharines were built in 1980 or earlier, according to the 2021 Census.

Older homes tend to have had many hands on their doors: owners, tenants, tradespeople, family. A locksmith visiting such a house pays attention to who holds keys now, and rekeying or a keyed-alike set often matters more than any new hardware.

56%

A mix of homes. Single-detached houses make up about 56% of homes in St. Catharines (2021 Census).

Where housing types are mixed, the same lost-key call means different things. In a house, rekey every door on the property. In an apartment, rekey the suite door and check with management about the common entrance. The locksmith asks which it is first.

Source: Statistics Canada, 2021 Census of Population

Open Facer in Google Maps

Open 24/7

Request a visit

The keypad on the side door has started sticking on cold mornings, codes get shared instead of reset, and half the staff still remember a code you meant to retire two hires ago.

Call now · open 24/7(289) 432-1115
  • On-site assessment preferred
  • Same fees day, night or weekend
  • 12 years in business